Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304

Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304
Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304

Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304 Specification

  • Filters
  • HEPA H14, Pre Filter
  • Air Flow
  • Vertical laminar flow
  • Condition
  • New
  • Application
  • Cleanroom
  • Material
  • SS304
  • Type
  • Vertical
  • Door
  • Front access acrylic door
  • Feature
  • Low noise, High-efficiency filtration
  • Filter Type
  • HEPA H14, Pre Filter
  • Dimension (L*W*H)
  • 3 ft x 3 ft x Standard Height
  • Lighting
  • LED
  • Floor
  • Stainless steel work surface
  • Frame Material
  • SS304
  • Voltage
  • 230 V AC
  • Front Sash
  • Transparent acrylic
  • Illumination
  • LED inside chamber
  • Orientation
  • Vertical
  • Blower Type
  • Centrifugal
  • Cleanroom Class
  • Class 100
  • Control Panel
  • Side mounted
  • Work Zone Height
  • 3 ft
  • Noise Level
  • <65 dB
  • Caster Wheels
  • Yes, for mobility
 

Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 1-2 Week
 

About Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304



Experience trending innovation with our Vertical Laminar Air Flow unit, proudly crafted in SS304 for unassailable cleanliness and radiant efficiency. Boasting a Class 100 cleanroom certification, it ensures incomparable particle control for every application. The centrifugal blower, paired with HEPA H14 and pre-filters, delivers powerful yet whisper-quiet performance (<65 dB), while the transparent acrylic front sash and side-mounted control panel enhance usability. Redeem mobility benefits with caster wheels and maintain flawless hygiene on a stainless-steel workspace-ideal for sensitive laboratory and industrial environments.

Material Excellence & Versatile Application

This Vertical Laminar Air Flow unit is constructed from premium SS304 stainless steel, offering robust durability for both general and specific cleanroom use. Its radiant vertical air flow is perfectly suited for contamination-sensitive tasks such as pharmaceutical, microelectronics, and medical applications. Easy to operate, users simply access the chamber via the acrylic front door and control settings from the conveniently side-mounted panel, ensuring seamless direction of use every time.


Fast Delivery, Certification & Global Markets

Our units are handed over with rapid dispatch-usually within days of order confirmation-thanks to dependable transport services. Each product comes fully certified for Class 100 performance and complies with international standards. As a leading exporter, manufacturer, and supplier in India, we offer these laminar flow units at a competitive sale price, catering to primary export markets in Asia, Europe, and the Middle East.


FAQ's of Vertical Laminar Air Flow, 3 ft Width, Class 100, SS304:


Q: How does the Vertical Laminar Air Flow unit maintain Class 100 cleanliness?

A: The unit utilizes a HEPA H14 filter and pre-filter in tandem with a centrifugal blower to create a uniform, vertical air flow, effectively removing airborne contaminants and sustaining Class 100 cleanroom standards.

Q: What materials are used in the construction of this laminar air flow unit?

A: It is constructed with high-grade SS304 stainless steel for the main structure and work surface, ensuring robust durability and easy cleaning, with a transparent acrylic front sash for clear visibility.

Q: When is the ideal time to use this equipment in a laboratory setting?

A: This unit is best used during sensitive laboratory operations such as sample preparation, microbial work, or device assembly, where particulate contamination must be kept at an absolute minimum.

Q: Where can the Vertical Laminar Air Flow unit be installed?

A: It is designed for cleanrooms, laboratories, pharmaceutical manufacturing areas, and any other controlled environments requiring superior cleanliness and particle control.

Q: What is the process for maintaining the HEPA filter in the unit?

A: The HEPA filter should be checked regularly for integrity and replaced according to the manufacturer's schedule or if a notable decrease in air flow or increase in noise is observed.

Q: What are the benefits of the vertical airflow direction in this unit?

A: Vertical airflow ensures that clean air moves directly downward, effectively sweeping contaminants away from the work zone and providing uniform particle-free conditions for highly sensitive operations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Clean Room Equipment Category

Horizontal Laminar Airflow

Horizontal Laminar Airflow

Price 35000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Galvanized steel

Voltage : 220 Volt (v)

Application : Laboratory

Air Shower Tunner

Air Shower Tunner

Price 375000.0 INR / Unit

Minimum Order Quantity : 1 Piece

Material : Stainless steel

Voltage : 220 Volt (v)

Application : Industrial

Class Ii Biosafety Cabinet

Class Ii Biosafety Cabinet

Price 70000 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Other, MS Powder Coated

Voltage : 230 V AC

Air Flow : Vertical Laminar

PCR Work Station

PCR Work Station

Price 25000 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Other, SS, Glass, Etc

Voltage : 230 V 50 Hz

Application : College, Hospital, Etc

Air Flow : Without Air