Cookie Img
Home » Products » General Laboratory Equipment

General Laboratory Equipment

Kjeldhal Digestion and Distillation
close
Kjeldhal Digestion and Distillation
36
The Kjeldhal method for the determination of organic nitrogen is the worldwide standard for the purpose of calculating the protein content in both human food and animal food. Additionally, Kjeldahl has been adapted as a standard method of nitrogen analysis in water, wastewater, fertilizer, and fossil fuels, to name a few. The Kjeldhal method for nitrogen analysis is composed of three distinct steps. These are digestion, distillation, and titration.
Ultrasonic Cleaner.
close
Ultrasonic Cleaner.
56
Soxhlet Extraction Unit.
close
Soxhlet Extraction Unit.
54
The equipment was originally designed for the extraction of a lipid from a solid material. However, a Soxhlet extractor is not limited to the extraction of lipids. Typically, a Soxhlet extraction is only required where the desired compound has a limited solubility in a solvent, and the impurity is insoluble in that solvent. If the desired compound has a high solubility in a solvent then a simple filtration can be used to separate the compound from the insoluble substance.
Black Prismatic Compass.
close
Black Prismatic Compass.
48
Black Prismatic Compass.
Microprocessor Spectrophotometer.
close
Microprocessor Spectrophotometer.
43
Digital Spectrophotometers is an economical, reliable, rugged and most accurate system for spectrophotometric analysis of any concentration. It operates at a wavelength range of 340 to 960 nm. Its outputs is available on 31/2 digital LED display in terms of optical density. Percentage transmission and concentration. Separate digital display is provided for wave length. Highly advanced solid state I.C Technology has made its circuit very stable and accurate. Desired wavelength can be selected by adjusting the knob at the top panel.
Microprocessor Flame Photometer
close
Microprocessor Flame Photometer
42
Specification of item: Four element measurements in a single aspiration (Na, K, Li, Ca, and Ba.) Calibration curve fit routines first order and second order. Data displayed in concentration units i.e. ppm & meq. automatic filter selection: auto calibration feature. Printer attached. PC connecting compatibility. Sample data storage more than 500 results. Alphanumerical key board for easy data enter, Graphical LCD display thus easy to read, Curve calibration facility. Stainless steel burner. Auto Gas Cut Off in case of power Failure. Provided with 2 filter & compressor
05
The Ball Mill operated electrically having a capacity from a few gram a few to 1 Kg. Fitted with DC Motor up to 2 Kg and AC Motor ¼ H.P heavy duty motor for 5 Kg jar. Maximum speed of 80 RPM. Jar is made of Stainless Steel having steel balls and MS ball of different size.
Lab Pulvrizer
close
Lab Pulvrizer
37
Laboratory Ball Mill
close
Laboratory Ball Mill
38
The laboratory ball mill takes care of any pulverizing, milling or grinding job that you can give it. Its multifunction design allows it to handle wet or dry, brittle or fibrous materials. This versatility, gives you the flexibility to replace your mills with one that can do any job, and do it right.
Gel Rocker Shaker
close
Gel Rocker Shaker
28
Gel Rocker is widely used in laboratory testing application. The rockers are extensively used as support equipment and features strong MS powder coated cabinet support as well as powder coated body that provides for uniform functional support. The Motion of platform is by means of Heavy Duty DC Motor with continuously variable electronic speed regulator which can be adjusted from 0 to 60 rpm.
Micro Fogger provides excellent control of droplet size, even for near-invisible 0.5-10 micron droplets needed by concentrated ULV chemicals. The Micro Fogger can treat 20-4,000 cubic feet per minute, reducing application time and labour-costs. And when you need high output and large droplets, the Micro Fogger is just as effective. It can deliver up to 150 ml/min in a mist of large (30 micron) droplets used in humidification, dust abatement and sanitizing work. The advanced Micro Fogger can apply either oil- or water-based chemicals. And it’s easy to calibrate when changing liquids.
Digital TDS Meter
close
Digital TDS Meter
24
Digital Spectrophotometer.
close
Digital Spectrophotometer.
23
Digital Spectrophotometers is an economical, reliable, rugged and most accurate system for spectrophotometric analysis of any concentration. It operates at a wavelength range of 340 to 960 nm. Its outputs is available on 31/2 digital LED display in terms of optical density. Percentage transmission and concentration. Separate digital display is provided for wave length. Highly advanced solid state I.C Technology has made its circuit very stable and accurate. Desired wavelength can be selected by adjusting the knob at the top panel
Digital Flame Photometer
close
Digital Flame Photometer
19
Flame photometers manufactured by us boast of top-notch quality. Supreme quality raw materials and properly updated technology is utilized for manufacturing them. Durability, longevity, strength, perfect designs are their highlights. Our top-notch quality experts, R&D team and engineers are responsible for developing products, with the latest trend in sight.
Crude Fiber Estimation
close
Crude Fiber Estimation
15
Technical Specifications Hot plate type for 6 tests, complete with 6 X 1000ml tall form Beakers, 6 Bulb shape condensers, clamps and connection rubber tube.
C.O.D Digestion Apparatus
close
C.O.D Digestion Apparatus
10
C.O.D Digestion Apparatus with digital controllers used to determine the chemical oxygen demand. It is a solid heater unit with provision for samples size to heat at temperature of 150-degree C ± 2 degrees. It has provision with glass reaction vessels and air condensers. Fitted with the 2 Hr. timer to work on 220/230V AC single phase supply.
Biochemistry Analyzer (Semi Automatic)
close
Biochemistry Analyzer (Semi Automatic)
07
The Bio-Chemistry Analyzer is mainly used for the quantitative analysis of the clinical bio-chemical items; it applies the lamber- beer law: A=kbc=lg(i0/i). Among them: a: absorbency, k: aspirated index, b: liquid layer’s thickness, c: solution’s consistency, i0: incident light’s strength, i: transmit light’s strength. According to the above formulas, under the condition of the certain liquid layer’s thickness and incident light’s strength, as long as test the strength of transmit light which goes through the liquid, so we can calculate the consistency of the solution.
Vertical Laminar Air Flow
close
Vertical Laminar Air Flow
41
Laminar Air Flows are conceptualized to provide a work area completely bathed in high efficiency perfect air, which is free from any kind of particulate contamination or impurities. These units are ideally suited in all the applications, requiring protection of biological specimens or products from the possible contamination during the process or test. The Laminar Air Flow clean bench pushes air through a H.E.P.A (High Efficiency Particulates Air) filter which is located at the top of enclosure. The air is directed downward onto the work surface at a constant speed. It is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.
Microprocessor UV-VIS Double Beam Spectrophotometer
close
Microprocessor UV-VIS Double Beam Spectrophotometer
58
UV-visible spectrophotometer, an analytical instrument commonly used in physic-chemical laboratories to make quantitative and qualitative analysis of specimen materials in the ultraviolet, visible spectral range finds much scope for its service in such fields as medicine, clinical examination, biochemistry, petro-chemical industry, Bio technology, Environmental protection and quality control. The technique has enjoyed a molecular biology and the need to quantify DNA and proteins. Here, the simplicity of use, the non-destructive nature of the sampling and the cost effectiveness of the measurement has proved very beneficial in the modern laboratory.


Send Inquiry